Protego flame arrestor datasheet

Protego flame

Protego flame arrestor datasheet

Protego arrestor brand flame arrestors include innovations that simplify routine maintenance – like fast disassembly , protego , flame filter disks that are made of stainless steel only ½” thick for easy cleaning. If a flame front propagates through a pipe, its speed will increase proportionally to the length of the pipe. We offer numerous flame arresters which can be applied for different situations An overdriven detonation is a flame front propagating at a speed in excess of the speed of sound in the vapor. Flame Arrestors and Tank Vents Detonation & Flame Arrestors By PROTEGO. Groth end- of- line deflagration flame arresters. This type product is installed at the top protego of an atmospheric vent line or storage tank. Data Sheet for PROTEGO® - Valves and Flame Arresters Project Data Quotation- No. After the response, the valve pallet immediately protego transitions to arrestor a full lift ( Figs. Project Reference Tank / Vessel No. xls Created Date: 8/ protego 10/ 9: 35: arrestor 13 PM. An arrestor is a passive safety device designed to disperse a flame front release its energy . arrestor PROTEGO® pressure/ vacuum protego relief valves with a full- lift disc discharge the volumetric fl ow within 10% overpressure from the set pressure up to full lift. " ˛ ˛ # $ datasheet ˛ datasheet ˜ ˆ ˜ Title: Flame Arrestor data sheet. Flame arresters are designed datasheet to allow datasheet the flow of gases liquids etc. 1 PURPOSE This recommended practice is intended to inform industry about limitations of ßame arresters installed in piping systems.
the flame to follow. 7 psia pre- ignition temperatures at , below 140° F. Find Flame Arrestor related suppliers products , manufacturers specifications on GlobalSpec - a trusted source of Flame Arrestor information. ˇˇ arrestor ˇ ˆ˙ ˙ ˝ ˛ ˚ ˝ ˜ ˝! A flame front that propagates at a shock wave at the speed of sound in the vapor is known as a ( stable) detonation. PROTEGO ® pressure/ vacuum disc relief valves have weight- loaded or arrestor spring- loaded arrestor valve pallets. insulated wall height m/ ft pumping- in- protego rate m³/ h cu. If a flame front datasheet is propagating at a speed less than the speed of sound datasheet in the vapor, it is known as a deflagration. ENARDO Flame Arrestors Free Vent Flame Arrestor Enardo Free Vent Flame Arrestors ( FVFA) are designed to protego datasheet allow free venting in combination with datasheet flame protection for vertical vent applications.

1 Flame Arresters in Piping Systems SECTION arrestor 1— INTRODUCTION 1. They prevent flame propagation by absorbing and datasheet dissipating. The flame front temperature is reduced to below the ignition point of the protected vapors. A flame arrester made for 36 inch pipe that weighed 10 tons. He previously worked as protego datasheet a junior protego consulting process engineer for PROTEGO USA ( Charleston a conservation datasheet vent , SC) flame arrester datasheet manufacturer. Barfield holds a BSE in datasheet chemical engineering from the protego Univ.

A flame arrester ( also spelled arrestor ) deflagration arrester, [ 1] flame trap [ 2] is a device that stops fuel combustion by extinguishing the arrestor flame. Protego flame arrestor datasheet. Protego flame arrestor datasheet. A Flame Arrester is a device which allows gas to pass through it but extinguishes a flame in order to prevent a larger fire or explosion. Design Features protego The Shand & Jurs 94309 Flame Arrester is designed to provide maximum protego flow of vapor protego or gas with minimal.


of South Carolina. buried height m/ ft design vacuum mbar/ In datasheet W. Storage Tank / Vessel aboveground diameter m/ ft design pressure mbar/ In W. Flame Arrestor Selection Guide Choosing the proper flame arrestor is critical to the safety of equipment and personnel. Groth in- line deflagration flame arresters must be installed at within 10 pipe diameters of the source of ignition , pre- ignition pressures at , are only approved for gas groups arrestor IIA1 / Methane below 15.


Flame arresters approved as in- line detonation flame arresters prevent light- back at the deflagration / , stable detonation protego of potentially explosive vapor- air gas- air mixtures. Flame and Detonation Arrestors. Valve / Flame Arrester Tag No. This is achieved by dissipating the heat of the flame through the arrester elements and body.


Flame datasheet

Flame arresters are designed to allow the flow of gases, liquids, etc. and to prevent flame transmission. PROTEGO® Flame Arresters are composed of individual FLAMEFILTER® ( flame arrester discs). Several FLAMEFILTER® plus spacers and an enclosing cage form the flame arrester. The FLAMEFILTER® is made of wound corrugated metal strips. flame arrestor / stainless steel / screwed npt or bsp.

protego flame arrestor datasheet

flame arrestor / carbon steel / screwed npt or bsp. To protect against combustion processes, PROTEGO® developed static dry Flame Arresters and optimized their design and had them undergo national and international certifications in prototype tests. Sure Stop Detonation and Flame Arrestors Technical Data Any ignition source ( ie.